Standard & Mini Size: Panels
Panels
Panel Assembly Standard Horizontal
Panel assembly for thermocouple and RTD circuits for mounting in control rooms, test stands, laboratory applications, pilot plants, etc.
Construction
This panel consists of the panel set 20.059-x fitted with the standard panel inserts PSI-… For further details see separate specification sheets.
- Accepts wires up to 3,0 mm.
Temperature rating
- 220°C Maximum
Ordering Code PAS-x-yz | x = number of circuits | 1, 2, 3, 4, 5, 6, 8, 12, 18, 24 |
y = calibration | E, J, K, N, T, U, R/S, C, B | |
z = color code standard | I = IEC, A = ANSI, D = DIN, J = JIS |
Circuits | Rows | Panel dimension (L x H in mm) | Dimension panel cut-out (in mm) |
1 | 1 | 38 x 38 | 31 ∅ |
2 | 1 | 70 x 67 | 40 x 40 |
3 | 1 | 89 x 67 | 49 x 40 |
4 | 1 | 108 x 67 | 78 x 40 |
5 | 1 | 127 x 67 | 97 x 40 |
6 | 1 | 146 x 67 | 116 x 40 |
8 | 1 | 184 x 67 | 154 x 40 |
12 | 1 | 260 x 67 | 230 x 40 |
18 | 1 | 374 x 67 | 344 x 40 |
24 | 2 | 260 x 115 | 230 x 88 |
Panels
Panel Assembly Standard Vertical
Panel assembly for thermocouple and RTD circuits for mounting in control rooms, test stands, laboratory applications, pilot plants, etc.
Construction
This panel consists of the panel set 20.060-x fitted with the standard panel inserts PSI-… For further details see separate specification sheets.
Wire size
- Accepts wires up to 3,0 mm.
Temperature rating
- 220°C Maximum
Ordering Code PASV-x-yz | x = number of circuits | 1, 2, 3, 4, 5, 6 |
y = calibration | E, J, K, N, T, U, R/S, C, B | |
z = color code standard | I = IEC, A = ANSI, D = DIN, J = JIS |
Circuits | Panel dimension (L x H in mm) | Dimension panel cut-out (in mm) |
1 | 72 x 116 | 30 x 40 |
2 | 72 x 116 | 50 x 40 |
3 | 72 x 116 | 62 x 40 |
4 | 72 x 116 | 80 x 40 |
5 | 72 x 116 | 94 x 40 |
6 | 72 x 116 | 112 x 40 |
Panels
Panel Assembly Standard High Temperature
Panel assembly for thermocouple and RTD circuits for mounting in control rooms, test stands, laboratory applications, pilot plants, etc.
Construction
Stainless Steel front panel for full corosion protection fitted with the standard high temperature panel inserts PSIH-… For further details see separate specification sheets.
Wire size
- Accepts wires up to 3,0 mm.
Temperature rating
- 350°C Maximum
Ordering Code PASVH-x-yz | x = number of circuits | 1, 2, 3, 4, 5, 6 |
y = calibration | E, J, K, N, T, U, R/S, C, B | |
z = color code standard | I = IEC, A = ANSI, D = DIN, J = JIS | |
Calibration indicated by colored dot on brown body. |
Circuits | Panel dimension (L x H in mm) | Dimension panel cut-out (in mm) |
1 | 72 x 116 | 30 x 40 |
2 | 72 x 116 | 50 x 40 |
3 | 72 x 116 | 62 x 40 |
4 | 72 x 116 | 80 x 40 |
5 | 72 x 116 | 94 x 40 |
6 | 72 x 116 | 112 x 40 |
Panels
Panel Assembly Standard High Temperature Three Pin
Panel assembly for thermocouple and RTD circuits for mounting in control rooms, test stands, laboratory applications, pilot plants, etc.
Construction
Stainless Steel front panel for full corosion protection fitted with the standard high temperature panel inserts PSIH-… For further details see separate specification sheets.
Wire size
- Accepts wires up to 3,0 mm.
Temperature rating
- 350°C Maximum
Ordering Code PASVHT-x-yz | x = number of circuits | 1, 2, 3, 4, 5, 6 |
y = calibration | E, J, K, N, T, U, R/S, C, B | |
z = color code standard | I = IEC, A = ANSI, D = DIN, J = JIS | |
Calibration indicated by colored dot on black body. |
Circuits | Panel dimension (L x H in mm) | Dimension panel cut-out (in mm) |
1 | 72 x 116 | 30 x 45 |
2 | 72 x 116 | 50 x 45 |
3 | 72 x 116 | 62 x 45 |
4 | 72 x 116 | 80 x 45 |
5 | 72 x 116 | 94 x 45 |
6 | 72 x 116 | 112 x 45 |
Panels
Panel Assembly Miniature Horizontal
Panel assembly for thermocouple and RTD circuits for mounting in control rooms, test stands, laboratory applications, pilot plants, etc.
Construction
This panel consists of the panel set 20.052-x fitted with the miniature panel inserts PMI-… For further details see separate specification sheets.
- Accepts wires up to 2,0 mm.
Temperature rating
- 220°C Maximum
Ordering Code PAM-x-yz | x = number of circuits | 1, 2, 3, 4, 5, 6, 8, 12, 18, 24 |
y = calibration | E, J, K, N, T, U, R/S, C, B | |
z = color code standard | I = IEC, A = ANSI, D = DIN, J = JIS |
Circuits | Rows | Panel dimension (L x H in mm) | Dimension panel cut-out (in mm) |
1 | 1 | 38 x 38 | 23 ∅ |
2 | 1 | 53 x 38 | 30 x 22 |
3 | 1 | 76 x 38 | 53 x 22 |
4 | 1 | 83 x 38 | 60 x 22 |
5 | 1 | 98 x 38 | 75 x 22 |
6 | 1 | 113 x 38 | 90 x 22 |
8 | 1 | 143 x 38 | 120 x 22 |
12 | 1 | 203 x 38 | 180 x 22 |
18 | 1 | 293 x 38 | 270 x 22 |
24 | 2 | 203 x 76 | 180 x 60 |
Panels
Panel Assembly Miniature Locking Horizontal
Panel assembly for thermocouple and RTD circuits for mounting in control rooms, test stands, laboratory applications, pilot plants, etc. When used together with CMLP the locking feature will prevent accidental disconnection due to vibration etc.
Construction
This panel consists of the panel set 20.400-x fitted with the miniature panel inserts PMLI-… For further details see separate specification sheets.
- Accepts wires up to 2,0 mm.
Temperature rating
- 220°C Maximum
Ordering Code PAML-x-yz | x = number of circuits | 1, 2, 3, 4, 5, 6, 8, 12, 18, 24 |
y = calibration | E, J, K, N, T, U, R/S, C, B | |
z = color code standard | I = IEC, A = ANSI, D = DIN, J = JIS |
Circuits | Rows | Panel dimension (L x H in mm) | Dimension panel cut-out (in mm) |
1 | 1 | 38 x 38 | 23 ∅ |
2 | 1 | 53 x 38 | 30 x 22 |
3 | 1 | 76 x 38 | 53 x 22 |
4 | 1 | 83 x 38 | 60 x 22 |
5 | 1 | 98 x 38 | 75 x 22 |
6 | 1 | 113 x 38 | 90 x 22 |
8 | 1 | 143 x 38 | 120 x 22 |
12 | 1 | 203 x 38 | 180 x 22 |
18 | 1 | 293 x 38 | 270 x 22 |
24 | 2 | 203 x 76 | 180 x 60 |